3.3: Display Information

The Nexus® 1262/1272 meter uses a graphical back-lit FSTN LCD Programmable Display with extend-
ed temperature voltage compensation. This allows you to view energy data and to gather circuit diagnos-
tic data such as voltage, current, harmonics and phasor information.
A wide range of values can be defined for display using the User Modes and screens in the
Programmable Display and Communicator EXT software. Three View Modes, plus Test Mode and a
Select Compensation Screen allow tremendous flexibility in setting up the Display modes and the
screens within the modes. View Modes are user created with up to 16 screens each, which display in
auto sequence every 7 seconds. Most of the screens have a Status Bar across the bottom which displays
the date, time and phase (if there are inputs). View Mode 1 is the primary mode. The other modes will
automatically return to View Mode 1 after a user-set amount of time from last user action.
Low Battery
Lo Batt - NVRam (Internal Battery) or Lo Batt - Modem (Modem Battery) will flash on
the screen being displayed every 10-15 seconds ONLY when the Internal (or Modem)
Battery is running low or when it is not "clicked" into place properly.
If the batteries are not low, NO INDICATOR will appear.
See installation instructions in sections 6.2 and 6.2.1.
Test Mode
Wh Test - Same as kWh screen, except in Wh instead of kWh
VARh Test - Same as kVAR screen, except in VARh (Quadrants)
VAh Test - Same as kVAh screen,except in VAh (Quadrants)
Watt Rolling Demand Test (Delivered and Received)
Watt Block Demand Test (Delivered and Received)
Initial Display Screens
The Nexus® 1262/1272 meter is shipped with Initial Display Screens, which will scroll on the
display as soon as you power up the meter. The Initial Display Screens are a sampling of the many
screens available for the Programmable Display, which is detailed in sections 3.4 to 3.7.
Typical Initial Display Screens:
Meter Data, including Boot, Run, DSP Boot, DSP Run, Serial Number, Protect Enabled, Baud
Wh Delivered
kVARh per Quadrant
Rolling W Demand Delivered
Block W Demand Delivered
W Demand Last Reset
Backlight
The Backlight cannot be set to stay on indefinitely. It will turn off after the amount of time selected.
One hour is the maximum setting. If the backlight has timed out and is off, you need to hit the
Mode Switch once to turn on the backlight and redirect the screen automatically.
Electro Industries/GaugeTech
Wh Received
kVAh per Quadrant
Rolling W Demand Received
Block W Demand Received
Cumulative W Demand
Doc # E151701
3-4