Figure 9.5: Nexus® P60N Touch Screen External Display - Electro Industries Nexus 1262 Installation & Operation Manual

Billing meters
Table of Contents

Advertisement

9.9: Nexus ® P60N Touch Screen External Display
The P60N Touch Screen External Display is ready to use upon power-up. Touching the "buttons" at
the top of the screen will take you to the Groups of Readings listed below. With the "buttons" at
the bottom of the screen, you can use the touch screen to review Limits and review and/or change
Settings on the Display and the Nexus® Monitor. Also, you can Reset Max/Min and Demand, Hour,
T Counters, All Logs and TOU for Current Session and Month using the Reset Button.
I
T and V
2
2
The P60N has a VA Rating of 5 and is powered by an external power source, such as the PSIO. See
Figures 6.9 and 6.11 for wiring detail.
All screens have a Main button that will take you back to the Main screen. All screens also have a
Next button that will take you to the next group of readings. Some of the screens have additional
navigation buttons to take you to complimentary readings. See section 9.10 for a navigational map.
General Page
Groups of Readings
Reset Button
GENERAL PAGE: Overview of Real Time
Readings
Volts AN/BN/CN/AB/BC/CA
Amps A/B/C
Watts
VARS
VA
FREQ
PF
Electro Industries/GaugeTech
View Limits
Figure 9.5: Nexus® P60N Touch Screen External Display
Doc # E151701
View / Change Settings
9-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 1271

Table of Contents