Features And Benefits - Hitachi FSG1 Series Technical Catalogue

Set-free outdoor and indoor units
Table of Contents

Advertisement

SYSTEM DESCRIPTION
1
/2
1.1

FEATURES AND BENEFITS

n
New HI-MULTI SET-FREE FSG(1) / FXG(1)
Series
HITACHI proudly introduces the New line up of SET FREE
FSG(1) 5-30 HP and FXG(1) 8-30 HP in order to respond
the request of air conditioning markets, for big capacity
units.
SET FREE series, are the highly-efficient ,reliable and
flexible in air conditioning system, for the markets.
Recently, increased numbers of buildings are requiring
"Intelligent" facilities - communication networks, office
automation, including a comfortable environment. In addition
to that, energy saving operation is needed. Particularly,
comfortable space is required all the day through the year in
shops and office buildings. This split air conditioner, " SET
FREE System " can meet these requirements. The proven
combination of the scroll compressor and the inverter
provides the best air conditioning for office buildings and
hotels.
§ New Outdoor units 24-30HP FSG1 and 20-30HP
FXG1
§ New CH-Box 11.5G
§ New Indoor units 2.0 and 2.5 RPF(I)
§ Connectable up to : Maximum 32 Indoor Units each
Outdoor Unit (30 HP) .
§ Maximum Total Combination horsepower of 130%
§ Refrigerant: R407C
n
Minimum and maximim combination of Outdoor and Indoor Units
Outdoor Unit Model
RAS-5FSG
RAS-8FSG
RAS-10FSG
RAS-16FSG
RAS-20FSG
RAS-24FSG1
RAS-30FSG1
RAS-8FXG
RAS-10FXG
RAS-20FXG1
RAS-30FXG1
CH-4.0GE
CH Unit
CH-6.5GE
Model
CH-11.5G
1) In case of changing the capacity from 1.0HP or 1.5HP to 1.3HP by DIP switch setting (see chapter 9).
2) In case that 1.0HP is used, the maximum quantity of 1.0HP indoor unit shall be 12
3) In case that 0.8HP or 1.0HP Indoor Units are used, the maximum quantity of 0.8HP and 1.0HP Indoor Unit shall be 10
4) In case that 0.8HP or 1.0HP Indoor Units are used, the maximum quantity of 0.8HP and 1.0HP Indoor Unit shall be 12
5) Simultaneous operation of cooling (dry) and heating is not available
Minimum
Maximum
Combination
Combination
Horsepower (HP)
Horsepower (HP)
2.5
6.5
4.0
10.4
5.0
13.0
8.0
20.8
10.0
26.0
12.0
31.0
15.0
39.0
4.0
10.4
5.0
13.0
10.0
26.0
15.0
39.0
0.8
Less than 4.0
0.8
Less than 6.5
0.8
6.5 and 11.5 (incl.)
n
Various Indoor units and combinations
The new line-up of new SET FREE series indoor units has
been extended up to 38 indoor units in 7 types to find
various building requirements .
Nominal Horsepower
Indoor Unit
Type
0.8
1.0
1.5
RCI-
-
O
O
RCD-
O
O
-
RPC-
-
-
RPI-
O
O
O
RPK-M
-
O
O
RPF-
O
O
-
RPFI-
O
O
-
O: AVAILABLE
Indoor Unit
Minimum
Maximum
Combination
Combination
of Indoor Unit
of Indoor Unit
1
2
2
2
13 (16)
2
2
2
2
2
2
2
1
1
1
(HP)
2.0
2.5
3.0
4.0
5.0
O
O
O
O
O
O
O
O
-
O
O
O
O
O
O
O
O
O
-
-
O(2.3)
O
O
-
-
O
O
-
-
Minimum
Individual
Operation
Horsepower (HP)
8
0.8
12
0.8
12
0.8
1
1
1.5 (1.3)
16
1.5
2
27
1.0
2
32
1.0
12
0.8
12
0.8
3
16
0.8
4
32
0.8
5
3
0.8
5
6
0.8
5
8
0.8
O
O
O
O
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsg seriesFxg seriesFxg1 series

Table of Contents