REMOTE CONTROLLERS OPERATION

11
/2

11.1 LIQUID CRYSTAL REMOTE CONTROL SWITCH (PC-P1HE)

Liquid Crystal Display (L.C.D) Section
Indication
Operation
Switch
Model:
PC-P1HE
Order No.: 7E799954
É É É É
Fan Speed Indicator
Ventilation Indicator
Indicates the fan speed you have selected:
(High/Medium/Low)
It indicates if Total Heat exchanger has been selected.
A/C only air conditioning
VENTI only ventilation
A/C + VENTI when both have been selected
Ê
Operation Mode Indicator
Indicates the operation mode selected:
Fan, Cool, Heat, Dry, Auto (Cool/Heat)
Ë
Run Indicator (Red Lamp)
Ì
RUN/STOP Switch
Í
MODE (Operation Mode Selection) Switch
Î
FAN SPEED (Fan Speed Selection) Switch
Ï
Up & Down Panel Operation Switch
Ð
VENTI(Ventilator Operation) Switch
Ñ
LOUVER (Swing Louver Operation) Switch
Ò
TIME (Time Setting) Switch
Increases and decreases the Set Time for timer
operation
Ó
ON/OFF TIMER Switch
Used to activate or deactivate the timer operation
Ô
CHECK Switch
Õ
RESET (Filter Reset Switch)
After cleaning the air filter, press the "RESET" button.
The filter indication Ø will disappear and the next
filter cleaning time is reset. It also stops the run
procedure.
Ö
TEMP (Temperature Setting) Switch
×
T.RUN (Test Run Indication)
Check (Check Indication)
These Tests appears when "TEST RUN" or "CHECK"
is being performed
Ø
ABNML (Alarm) Indicator
"FILTER" Indicator
Ù
SET TEMP (Setting Temperature) Indicator
Ú
ON/OFF Timer (Timer Operation Indicator)
Alarm Code Indicator
"NO FUNCTION" Indicator
Û
CENTRAL (Central Control Indicator Operation)
Indicates that central station or CS-Net is being
performed
Ü
Swing Louver Indicator
"DEFROST" Indicator
When opening the cover,
pull the cover toward the arrow direction
?
NOTE:
– Do not use this system as constant temperature and
constant humidity control equipment.
– In the case that the LOW fan speed is selected and
outdoor temperature is higher than 21°C, excessive
load is given to the compressor at heating operation.
Therefore, set the fan speed at HIGH or MEDIUM,
since safety devices may be activated.
– When the system is started after a shutdown longer
than approximately 3 months, it is recommended that
the system be checked by your service contractor.
– Turn OFF the main switch when the system is stopped
for a long period of time. If the main switch is not
turned OFF, electricity is consumed, because the oil
heater is always energized during compressor
stopping.