Page Commands (Cont.)
@PSE
@PSP
@PST
PAGE
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
Set the show effect for the specified popup page to the named show effect.
Syntax:
"'@PSE-<popup page name>;<show effect name>'"
Variables:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed
On.
show effect name = Refers to the popup effect name being used.
Example:
SEND_COMMAND Panel,"'@PSE-Popup1;Slide from Left'"
Sets the Popup1 show effect name to 'Slide from Left'.
Set the show effect position.
Only 1 coordinate is ever needed for an effect; however, the command will specify both.
This command sets the location at which the effect will begin at.
Syntax:
"'@PSP-<popup page name>;<x coordinate>,<y coordinate>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed
On.
Example:
SEND_COMMAND Panel,"'@PSP-Popup1;100,0'"
Sets the Popup1 show effect x-coordinate value to 100 and the y-coordinate value to 0.
Set the show effect time for the specified popup page.
Syntax:
"'@PST-<popup page name>;<show effect time>'"
Variables:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed
On.
show effect time = Given in 1/10ths of a second.
Example:
SEND_COMMAND Panel,"'@PST-Popup1;50'"
Sets the Popup1 show effect time to 5 seconds.
Flips to a page with a specified page name.
• If the page is currently active, it will not redraw the page.
Syntax:
"'PAGE-<page name>'"
Variable:
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
Example:
SEND_COMMAND Panel,"'PAGE-Page1'"
Flips to page1.
Programming