Wireless Settings Page; Secondary Connection Page; Wireless Security Page - AMX NXD-1000Vi Operation/Reference Manual

10" modero wall/flush mount touch panel with intercom
Hide thumbs Also See for NXD-1000Vi:
Table of Contents

Advertisement

Type
Mode
System Settings Page Elements (Cont.)
Master Connection (Cont.):
System Number
Master IP/URL
Master Port Number
Username/Password
Refer to the Step 3: Choose a Master Connection Mode section on page 49 for more detailed information
on using the System Settings page.

Wireless Settings Page

Use the options on the Wireless Settings page (FIG. 73) to configure communication settings for the
wireless CF card (802.11g), and read the device number assigned to the panel.
Features on this page include:

Secondary Connection Page

The Secondary Connection page sets the communication information for an installed wireless interface
card. The NXD-CV5 Touch panel is not enabled for wireless communication and therefore, this page is
not user-editable.

Wireless Security Page

The options on the Wireless Security page allow you to select from the wireless security methods
supported by the NXA-WC80211GCF Wi-Fi card. These security methods incorporate WPA, WPA2, and
EAP technology (some of which require the upload of unique certificate files to a target panel).
Refer to the Appendix B - Wireless Technology section on page 1 for more further information.
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
Sets the NetLinx Master to communicate with the panel via either USB or
Ethernet. This is based on the cable connection from the rear.
ICSNet is not a supported option on this panel.
• Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication.
• USB option cannot be used on Modero panels which are not equipped with a
rear USB port.
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
• URL - In this mode, enter the IP/URL, Master Port Number, and
username/password (if used) on the Master.
- The System Number field is read-only because the panel obtains this
information from the communicating Master.
• Listen - In this mode, add the Modero panel address into the URL List in
NetLinx Studio and set the connection mode to Listen. This mode allows the
Modero touch panel to "listen" for the Master's communication signals.
- The System Number and Master IP/URL fields are red-only.
• Auto - In this mode, enter the System Number and a username/password
(if applicable). This mode is used when both the panel and the NetLinx
Master are on the same Subnet and the Master has its UDP feature enabled.
- Master IP/URL field is read-only.
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Allows you to enter the port number used with the NetLinx Master.
• Default value is 1319. (ETHERNET Only - disabled when USB is selected)
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
Firmware Pages and Descriptions