Configure A Virtual Netlinx Master Using Netlinx Studio - AMX NXD-1000Vi Operation/Reference Manual

10" modero wall/flush mount touch panel with intercom
Hide thumbs Also See for NXD-1000Vi:
Table of Contents

Advertisement

FIG. 46
USB driver installation popup window
8.
Click Yes to proceed with the driver installation.
9.
Navigate back to the System Settings page.

Configure a Virtual NetLinx Master using NetLinx Studio

A Virtual NetLinx Master (VNM) is used when the target panel is not connected to a physical NetLinx Master.
In this situation, the PC takes on the functions of a Master via a Virtual NetLinx Master. This connection is
made by either using the PC's Ethernet Address (via TCP/IP using a known PC's IP Address as the Master) or
using a direct mini-USB connection to communicate directly to the panel.
Before beginning:
1.
Verify the panel has been configured to communicate via USB within the System Settings page and that
the USB driver has been properly configured. Refer to the previous section for more information.
2.
In NetLinx Studio, select Settings > Master Communication Settings, from the Main menu to open the
Master Communication Settings dialog (FIG. 47).
IP Address of computer
(not needed as this is a
direct USB connection)
FIG. 47
Assigning Communication Settings for a Virtual Master
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
Once the installation is complete, the panel and PC are ready to communicate via USB.
Configuring Communication
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents