A.6.2  Block Converter (Buc/Bdc) Remote Commands And Queries - Comtech EF Data MBT-5003 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
Appendix A
A.6.2
Block Converter (BUC/BDC) Remote Commands and Queries
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Attenuation
ATT=
5 bytes,
Operating RF
FRE=xxxxx.x
9 bytes
Frequency
xx
Global
GCC=
variable length
Converter
Configuration
Mute State
MUT=
1 byte
Description of Arguments
(Note that all arguments are ASCII numeric codes
to Query
Command or Query.
Valid attenuation level (00.00 to 50.00 for x-band BUC units, 00.00
to 20.00 for all other), in dB, in 0.25 dB steps as factory default.
Default Value: 00.00
Example: <2/ATT=12.25'cr'
>0002/ATT='cr''lf'
Note: Attenuation cannot be changed for the offline unit when in
redundancy mode.
Command or Query.
Valid Operating RF frequency, in MHz.
For Ku BDCs only:
FRE values: 10950-11700 MHz an LO of 10000 MHz is activated
FRE values: 11700-12250 MHz an LO of 10750 MHz is activated
FRE values: 12250-12750 MHz an LO of 11300 MHz is activated
Example: FRE=11300.000'cr'
Note: Operating Frequency cannot be changed for the offline unit
when in redundancy mode.
Command or Query.
Used to set up and query the global status of the BUC/BDC.
Example: GCC=aa.aa;b;ccccc.cc; 'cr' where:
aa.aa = attenuation in dB (ATT)
b = mute state, 0 = un-muted, 1 = muted (MUT)
ccccc.ccc = frequency in MHz (FRE, Ku BDC only, other units will
display xxxxx.xxx)
Note: This command can only be queried for the offline unit when
in redundancy mode.
Command or Query.
Mute the unit, where:
0 = Disabled (Not Muted)
1 = Enabled (Muted)
Default Value: 0
Example: <2/MUT=1'cr'
>0002/MUT=1'cr''lf'
Note: Mute State cannot be changed for the offline unit when in
redundancy mode.
between 48 and 57)
A–17
Response to
Query
Command
(Instruction
(Target to
Code and
controller)
qualifier)
ATT=
ATT?
ATT=xx.xx
ATT?
ATT*
(Same format as command
arguments)
FRE=
FRE?
FRE=x....x
FRE?
FRE*
(See Description of
Arguments)
GCC=
GCC?
GCC=x....x
GCC?
GCC*
(See Description of
Arguments)
MUT=
MUT?
MUT=x
MUT?
MUT*
(same format as command
arguments)
Revision 1