Power In (Iec Line Input Ac Power) Connector; Ground Connector - Comtech EF Data MBT-5003 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
External Connectors
3.2.2.6

POWER IN (IEC Line Input AC Power) Connector

For continued operator safety, always replace the fuses with the correct type
and rating.
IMPORTANT
Observe the following:
Input Power
Input Voltage
Connector Type
Fuse Protection
3.2.2.7

Ground Connector

A #10-32 stud is used for connecting a common chassis ground among equipment.
Note: The AC power connector provides the safety ground.
A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the converter.
AC Power Specifications
290W maximum, 110W typical.
100 to 240 volts AC, +6/-10% - autosensing
(total absolute max. range is 90 to 254 VAC)
IEC-320
T2A (2.0A) Slow-blow
Line and neutral fusing
20 mm type fuses
3–5