Buc-5003 Block Up Converter (Featured On Mbt-5003-Xur) - Comtech EF Data MBT-5003 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
Introduction
1.4.5

BUC-5003 Block Up Converter (featured on MBT-5003-XUR)

Output Frequency
Input Frequency
Frequency Sense
Impedance
Input Return Loss
Output Return Loss
Input Connector
Output Connector
Full Band
Gain
Per 36 MHz
Per 20 MHz
0° to +56° C
Mute
User Attenuation Range
Output Power, P1dB
Noise Figure
Intermodulation Distortion
AM/PM Conversion
Carrier Related
Spurious (In-band)
Non-Carrier Related
Lo Leakage
Related
60 Hz & Harmonics
Per 20 MHz BW
Phase Non-linearity
Per 36 MHz BW
100 Hz
1 kHz
Phase Noise
10 kHz
100 kHz
1 MHz
7900-8400 MHz
1000-1500 MHz
No Inversion
50Ω
15 dB minimum
18 dB minimum
Type 'TNC' Female
Type 'N' Female
38 ±2 dB nominal @ minimum attenuation
±1.0 dB
±0.50 dB
±0.35 dB
.75 dB/15°C (±1 dB, 0°-56 °C)
80dB
0-50 dB, in 0.25 dB steps
22 dBm minimum
15 dB @ minimum attenuation
-30 dBc min w/2 output carriers @ 17 dBm each
0.1°/dB @ 0 dBm Output
-75 dBc (<-80 dBc, typical)
-70 dBm
-75 dBm
<-36 dBc (typically <-50 dBc)
8 degrees p-p
12 degrees p-p
Meets or exceeds MIL-STD-188-164A
-68 dBc/Hz
-78 dBc/Hz
-88 dBc/Hz
-98 dBc/Hz
-108 dBc/Hz
1–7
Revision 1
MN-MBT5003