Comtech EF Data MBT-5003 Installation And Operation Manual page 86

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
Appendix A
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Faults and
N/A
4 bytes
Status
Retrieve
N/A
variable length
Firmware
Number
Initialize
IEP=
None
Events Pointer
Software
IMG=
1 byte
Image
Description of Arguments
(Note that all arguments are ASCII numeric codes
to Query
Query Only.
Unit returns the current fault and status codes for the Base Unit,
Converter A and B, in the form abcd, where:
a = Base Unit Faults:
0 = No faults
1 = +12V Power Supply 1
2 = +12V Power Supply 2
3 = +5V Power Supply 1
4 = +5V Power Supply 2
5 = +7.8V Power Supply
6 = Flash Checksum
7 = FPGA Done
8 = External Ref Lock Detect
9 = Converter A Not Inserted
A = Converter B Not Inserted
B = Switch Fault
b, c = Converter A and B Faults:
0 = No faults
1 = Synthesizer Lock Detect
2 = Heat-sink Temperature
3 = Low Forward RF Power (BUC only)
d = New Faults:
0 = No change in fault status since last check
1 = Change in fault status, since last check
Query only.
Returns the firmware type loaded into the unit.
i = Bulk Image Number (1 or 2)
a = Firmware Image
b = Firmware Revision
c = Firmware Date
Command only.
Resets internal pointer to allow RNE? Queries to start at the
beginning of the stored events log.
Example: IEP=
Command or Query.
Current Active software image, where:
1=Bulk Image # 1 currently active
2=Bulk Image # 2 currently active
Example: IMG=1 (which is Image #1 active)
between 48 and 57)
A–10
Response to
Query
Command
(Instruction
(Target to
Code and
controller)
qualifier)
N/A
FLT?
FLT=abcd
d=Change in fault status
since last poll.
Note: Each section has
faults listed in order of
priority. For each section,
only the highest priority
fault is returned. There may
be multiple faults for each
section, but only the
highest fault is returned.
N/A
FRW?i
FRW={CR}Boot:{CR}abc{C
R}Bulki:{CR}abc{CR}abc
(See Description of
Arguments)
IEP=
N/A
N/A
IEP?
IEP*
IMG=
IMG?
IMG=x
IMG?
IMG*
(See description of
IMG#
arguments)
Revision 1
MN-MBT5003
Response to query
(Target to controller)

Advertisement

Table of Contents
loading