Utility: Firmware Select; Select: Test - Comtech EF Data MBT-5003 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
Front Panel Operation
If, for example, Bulk is selected, a screen formatted similar to the following example is
displayed:
Bulk: FW-0000303
2.#.# MM/DD/YY
UTILITY: Firmware
If Select is selected:
Current Active Image: #1
Next Reboot Image: #1 #2
The top line shows the current active image. From the bottom line, select the Next Reboot Image
(i.e., the image that will be active the next time the unit is rebooted) as #1 or #2 using the
arrow keys. Press ENT when done.
5.3.5

SELECT: Test

TEST: Lamptest
Press ENT to begin the diagnostics run on the front panel's Light-Emitting Diode arrays and
Vacuum Fluorescent Display. The LEDs for Unit A and Unit B will cycle, and the VFD will briefly
generate a test pattern.
Once the test has run, press CLR to return to the SELECT: (Main) menu.