MBT-5003 L-Band Up/Down Converter System
Ethernet Management
•
Clear Events Log: Select to clear all stored events from the log.
•
Initialize Events Pointer: Select to reset the internal pointer to allow queries to start at
the beginning of the stored events log.
Once a selection has been made, click [Submit] to execute the choice – the window will update
according to the selection made.
Alarm Mask
Note the following:
•
Low Noise Amplifier (LNA) operation is not supported by the MBT-5003. All alarm masks
associated with this feature are therefore nonfunctional.
•
The Low Forward RF Power alarm masks are valid, when optionally configured, only for
the MBT-5003-XUR Up Converter.
Using the drop-down menus, select each alarm as Fault, Alarm or Masked for:
•
Low Forward RF Power (MBT-5003-XUR only)
•
Converter A Not Inserted
•
External Reference Lock Detected
•
Converter B Not Inserted
Once the desired configuration settings have been made in this section, click [Change Alarm
Mask] to save these changes. Otherwise, click [Reset] if it is desired to revert back to the
previously assigned Alarm Mask settings, the user should instead click.
6–19
Revision 1
MN-MBT5003