Comtech EF Data MBT-5003 Installation And Operation Manual page 90

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
Appendix A
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Retrieve Next
N/A
75 bytes
5 unread
stored Events
Description of Arguments
(Note that all arguments are ASCII numeric codes
to Query
Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body= ABCddmmyyhhmmss:
A being the fault/clear indicator.
F = Fault
C = Clear
I = Info
B being the fault type where:
1 = Base Unit
2 = Converter A
3 = Converter B
C is Fault Code numbers
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
between 48 and 57)
A–14
Response to
Query
Command
(Instruction
(Target to
Code and
controller)
qualifier)
N/A
RNE?
RNE={CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss
(See Description of
Arguments)
Revision 1
MN-MBT5003
Response to query
(Target to controller)

Advertisement

Table of Contents
loading

Table of Contents