Symbol PDT 1100 Product Reference Manual page 59

Hide thumbs Also See for PDT 1100:
Table of Contents

Advertisement

2. Select one of the following:
Press 1 to activate the resume function which resumes the display shown
Press 2 to deactivate the resume function.
3. Press ENT to enter your selection, or C to return to the Set System menu.
Setting Communications Environments
After the PDT 1100 is initialized, the interface port and communications parameters are set
as listed in the default tables below. Do not access them unless necessary.
Interface Port
Communications protocol
Communications parameters for the optical
interface port
TRANSMIT SPEED
PULSE WIDTH
(Output pulse width of IR beam)
PROTOCOL
(Protocol options)
Table 4-4. Comm. Parameter Default for Direct-Connect Interface
Communications Parameters
TRANSMIT SPEED
PARITY BIT
DATA BIT (Character length)
STOP BIT
Table 4-3. Interface Port Parameters Default
Parameter
OPT (Optical interface port)
protocol
9600 bps
1.63 ms
SERIAL No. ON: Adds serial numbers to data
blocks.
Adds a horizontal parity.
LINKUP TIME: 30 seconds
FIELD SPACE: Ignore
Defaults
19200 bps
None
8 bits
1 bit
System Mode
Default
4-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents