Repairs/Adjustments

REP 20 CRUM PBA

Phaser 3200
Parts list on
PL 8.1
1. Remove the scan assembly,
2. Remove the middle cover,
3. Remove the HVPS,
4. Remove 2 screws securing the CRUM
housing and remove it, Figure 1.
Figure 1
4-40
REP
8.
REP
12.
REP
13.1.
5. Disconnect 3 connectors from the main
PBA and SMPS, Figure 2.
6. Carefully release the CRUM harness (with
the CRUM PBA) below the bottom of the
engine shield in the direction of the arrow,
Figure 3.
04/07
Phaser 3200MFP / Workcentre PE220
Figure 2
Figure 3