SMPS & HVPS
It is the power supply for the entire system. It is assembled as an independent module, so it is
possible to use for common use. It is mounted at back of the machine. Power part is divided by
two independent PBAs - SMPS PBA and HVPS PBA. SMPS PBA supplies the DC power for driv-
ing the system and supplies the AC power to the fuser.
SMPS has two output channels: +5V and +24V. HVPS PBA supplies High voltage to the develop-
er part to make a printing image on the paper. High voltages applied to the MHV, THV, DEV, SUP-
PLY.
SMPS
1. AC Input
- Input Rated Voltage: AC 220V ~ 240V / AC 110V ~ 127V
- Input Voltage fluctuating range: AC 180V ~ 270V / AC 100V ~ 135V
- Rated Frequency: 50/60 Hz
- Frequency fluctuating range: 47 ~ 63 Hz
- Input Current: Under 4.0Arms / 2.5Arms
2. Rated Output Power
NO
Items
1
CHANNEL
2
CONNECTOR PIN
3
Rated Output
4
Max. Output current
5
Peak Loading current
6
RIPPLE NOISE
7
Maximum output
8
Peak output
9
Protection for loading
shortage and
overflowing current
3. Consumption Power
NO
Items
1
Stand-By
2
Printing
3
Sleep-Mode
Phaser 3200MFP / Workcentre PE220
Table 3:
CH1
+5V
CON 2
5V PIN: #5pin
GND PIN: #6pin
+5V ± 5%(4.75 ~ 5.25V)
0.8 A
1.0 A
100mVp-p or less
2.5W
4W
Fuse Protection or Shut-
down within 1.5A ~ 3.0A
range.
Table 4:
CH1(+5V)
0.6 A
0.8 A
0.5 A
04/07
General Procedures and Information
CH2
+24.0V
CON 2
24V PIN: #2, #3, #4
GND PIN: #7pin
+24V -10%/+15%(21.6V ~
27.6V)
2.5 A
2.7 A
500mVp-p or less
36W
55.2W
Fuse Protection or Shut-
down within 3.5A ~ 4.5A
range.
CH2(24V)
1.3 A
1.9 A
0.3 A
Remarks
Jam cover switch
included
within 1ms Duration
1ms
System
AVG: 65Wh (PE220)
70Wh (Phaser 3200)
AVG: 350Wh (PE220)
400Wh (Phaser 3200)
AVG: 10Wh (PE220)
12Wh (Phaser 3200)
6-25