REP 15 CRUM PBA

Parts list on PL 3
WARNING
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the LSU. (Refer to REP 10)
2. Remove the Engine Shield Assembly.
(Refer to REP 12)
3. Remove 4 screws, then the CRUM PBA,
Figure 1.
Figure 1
WorkCentre 3119

REP 16 Transfer Roller

Parts list on PL 1
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the LSU. (Refer to REP 10)
2. Remove 3 screws, then the Transfer
Earth, Figure 1.
3. Disconnect the PTL PBA Harness then
remove the PTL Holder and PTL Lens,
Figure 2.