Repairs/Adjustments
REP 16.0 Fuser Assembly
Workcentre PE220
Parts list on
PL 7.0
WARNING
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Do not touch the fuser while it is hot.
1. Remove the scan assembly,
2. Remove the middle cover,
3. Unplug the 2 connectors from the SMPS
and Main PBA, Figure 1.
Figure 1
4-28
REP
8.
REP
12.
04/07
4. Remove 4 screws securing the fuser and
remove it, Figure 2.
Figure 2
5. Remove the Lever-M-Act exit in the direc-
tion of arrow, Figure 3.
Figure 3
Phaser 3200MFP / Workcentre PE220