Scte-104 Insertion And Extraction Setup Examples - Imagine Selenio X100 Installation And Operation Manual

Intelligent dual?channel frame synchronizer and converter
Table of Contents

Advertisement

66
Selenio X100
Installation and Operation Manual

SCTE-104 Insertion and Extraction Setup Examples

Inserting SCTE-104 Packets on Line 10 Using GPI Triggers
Follow these steps to insert SCTE-104 packets using GPI triggers:
1
First configure each GPI input to Rising Edge for SCTE-104 triggers:
a
At GPI and Rules Engine > GPI > GPI Direction, set all 8 GPIO Direction to Input
options.
b
Go to Data > Advanced Status and Control > SCTE-104 and then set the following:
i.
SCTE104 Trig Mode > GPI
i.
SCTE104 GPI Trigger Enable/Disable > Yes
c
At GPI and Rules Engine > GPI > GPI Input, select GPI Input to Edit > GPIO 0, and
then set Event to SCTE104/BT1685 Control.
d
Repeat the above for all 8 GPI inputs.
2
Apply a pulse at GPI0 input port.
3
Enable GPI port 0 of the 8 GPI input ports for the SCTE-104 trigger:
a
At GPI and Rules Engine > GPI > GPI Input, select GPI Input to Edit > GPIO 0, and
then set Trigger to RisingEdge.
b
Go to GPI and Rules Engine > GPI > GPI Input and then set GPI Input to Edit to
GPIO 1, and set Trigger to Off
c
Repeat the above (set Trigger to Off) for each of GPIO parameters 2 through 7.
4
Set up the SCTE-104 embedder to embed the SCTE-104 trigger on line 10 of video output 1
a
Go to Data > Output > Proc Ch 1 Output.
b
Select Trigger SCTE-104 in Proc Ch 1 LN 10.
For other GPI input ports, select the GPI Input to Edit and then set trigger to Rising Edge.
Note:
Only one of the eight GPI input triggers will be accepted during any video frame
period, GPI port 0 will have the highest priority and GPI port 7 will have the least priority.
SCTE-104 Packets Data Extraction
1
Connect a video input with SCTE-104 packets to Proc Channel 1 Input (SDI 1) and then
select Video > Video Input > Input Routing > Proc Ch 1 Source > SDI 1 Input.
2
Set up SCTE-104 de-embedder on video input 1
At Data > Input > Proc Ch 1 Input, select in Proc Ch 1 Data Input View > Line
View. SCTE-104 displays on Proc Ch 1 Line xx.
3
Check SCTE-104 packet information extraction.
View the extracted AS Index, DPI PID Index and Time Type at Data > Advanced
Status and Control > SCTE-104 > Packet Extraction > Last Received Monitor
> Multiple Operation.
View the extracted Insert Type, Event Source, Unique Program ID, Pre-roll
Time, Break Duration, Avail Num and Avails Expected at Data > Advanced
Status and Control > SCTE-104 > Packet Extraction > Last Received Monitor
> Splice Request Data.
View the DTMF Pre-roll Time and DTMF Input at Data > Advanced Status and
Control > SCTE-104 > Packet Extraction > Last Received Monitor > DTMF
Descriptor Data.