Data Output And Data Bridging; Vbi Line Delete; Generic Vanc Data Passing; Vbi Transfer - Imagine Selenio X100 Installation And Operation Manual

Intelligent dual?channel frame synchronizer and converter
Table of Contents

Advertisement

62
Selenio X100
Installation and Operation Manual

Data Output and Data Bridging

VBI Line Delete

Generic VANC Data Passing

VBI Transfer

Dual Link Support

For each SDI output blanking line, you can select up to two kinds of data to be embedded
into the same line. Source data can be routed from the same processing channel input or
bridged from a different processing channel input. Source data can also be routed from the
audio metadata generator, serial-triggered data, or GPI-triggered data. (When two
conflicting data types are selected for the same line, the Output Selection Status displays
an error message.)
There are up to two data selections per line when selecting data to embed into an SDI
output. To adjust the number of visible embedding controls for a particular VBI line, set
Data Output > Proc Ch x Output >
Number of Data on Line x parameter for that line.
For outputs other than SDI, you can select data for LTC, serial, or GPI output.
For each SDI VBI line data embedding selection, you can select VBI Line Delete to remove
everything on that line. If the output standard is interlaced, a field selection parameter (VBI
Delete Field LN x) is enabled, which will then allow you to select which field to apply the
VBI deletion to. Options for VBI Delete Field LN x are: 1st Field, 2nd Field, and Both
Fields (default).
Up to 10 different types of VANC data packets (specified by the DID/SDID) can be routed
from the SDI input to the SDI output. The system can also automatically identify the newly
detected DID/SDID, and fill the detected value into the first available empty DID/SDID
control.
When Data Auto Pass is set to Yes at Advanced Data Status and Control >
General, the output embedding will also automatically pass the newly discovered data into
the output.
The VBI Transfer parameter makes it possible to transfer all VBI/VANC data (excluding the
data in the HANC region) transparently from the input to the output. (VBI Transfer is only
available when the input and output video standards are the same.)
If the VBI transfer is disabled, you will need to manually configure the data embedder to
embed the VBI/VANC data you require at the output. This is because the X100 (except
when operating in Proc Bypass mode) strips out all VBI/VANC data from the
performing video processing and scaling. The VBI Transfer control is located at Data
Output > Proc Ch x Output.
If a dual link video standard is used, the Link Selection control
and Control > General) makes it possible to select which link
de-embedding and embedding VANC data.
Line to Edit to the target line, then adjust the
system should be used when
video when
(Advanced Data Status