Change the IP address by following these steps:
a
Press Enter to navigate to one of the four number sets in the octet.
b
Modify the address value by using the scroll knob to set a new number.
c
Press Enter to move to the next item in the octet, and then repeat step (b) above.
d
Press Exit when you are finished configuring the address.
4
Scroll to the Subnet Mask parameter, and then press Enter.
If this is a new unit being configured, the default subnet mask displays. Otherwise, the
current subnet displays.
5
Repeat the procedure described in step 4, this time for the subnet mask.
6
Scroll to the Gateway parameter, and then press Enter.
If this is a new unit being configured, the default gateway displays. Otherwise, the current
gateway address displays.
7
Repeat the procedure described in step 3, this time for the gateway parameter.
8
Select Save IP, and then press Enter.
9
Select Yes option and then press Enter.
Press Exit to return to the Setup menu.
Rebooting the Selenio X100 is not required.
Setting the IP Addresses of Multiple Units
If you have multiple Selenio X100 systems that require network configuration, you will need
to set unique IP addresses and assign a subnet mask and gateway address for each of them
one at a time. The following procedure summarizes the required steps:
1
Apply power to the first Selenio X100 unit with a frame-mounted local control panel.
When ready for configuration, the main Selenio X100 menu shows on the display screen.
2
Configure the network settings for the first Selenio X100, as described in the procedure on
page 17.
3
Restart the Selenio X100 unit.
4
Plug in the next Selenio X100 system, configure its network information, and then restart
the unit.
Follow this procedure for all remaining Selenio X100 units that require configuration.
5
Connect all Selenio X100 systems and remote panels to a network hub or switch using a
10/100Base-T Ethernet cable.
6
Ensure that all configured Selenio X100 units are detected on the network.
To do this, press Remote on the front panel. All Selenio X100 units configured with the
same subnet mask address will display (you will see a list of all detected IP addresses).
If a unit or RCP is not detected, ensure that the subnet mask address is accurate.
Alternatively, confirm that all units were restarted after configuring any network settings.