The outputs include four HD-BNC SDI connectors, two SFPs, one HDMI output, and two
analog (composite or SD/HD component) video HD-BNCs (requires optional analog
submodule).
The following format options are available:
Table 3-3 Proc Ch 1 and 2 Out Format Options
Follow Ref
1080i/59.94
Proc Bypass
1080i/60
525
1080i/50
625
1080p/23.98
720p/59.94
1080p/24
720p/60
1080p/25
720p/50
1080p/29.97
All outputs carry the converted program signal or a frame sync signal. Conversion is
automatic, based on your selected output video standard; the converted program signal
carries the following:
Embedded audio
ARC data (WSS/VI/AFD)
CC/TT
BrandNet
Timecode
Closed captioning
Lidia
SCTE-104
BT-1685
ARIB
Cue data
BT-1685
SCTE-104
Output Frame Rate
The Output Frame Rate control enables basic automatic frame rate conversion (FRC).
(A higher quality linear frame rate converter is also available by switching to the Linear FRC
mode, found at Video Output and Routing > Operation Mode. The Linear FRC requires
the purchase of the X100OPT-SK-SC. See page 32)
Using the basic automatic Output Frame Rate, audio/video alignment is variable ±1 frame.
There must be a valid reference available for the selected output standard. If the input
signal has a different frame rate from the output frame rate, the FRC is enabled
automatically. In this mode, two independent channels are operating at the same time. One
or both of the channels can be used for frame rate conversion.
Options for the Output Frame Rate parameter are Follow Ref (auto detection of external
genlock source), 29/59 Hz, 25/50 Hz, and 30/60 Hz.
Installation and Operation Manual
1080p/30
1080p/60
1080PsF/23.98
1080p/50
1080PsF/24
1080p/59.94 DL
1080PsF/25
1080p/60 DL
1080PsF/29.97
1080p/50 DL
1080PsF/30
1080p/59.94
Selenio X100