Loudness Control Parameters
Table 4-10. DTS Neural Audio Loudness Control Parameters
Parameter Name
Loudness Control Function
Loudness Control Status
Target Loudness Level
LC Ratio
Upper Threshold
Lower Threshold
Freeze Window
Quiet Threshold
Attack Time
Release Time
Compressor Threshold
Compressor Ratio
Loudness Shaping
Final Limiter Ceiling
Metering
Current Input Loudness
[RO]
Current Input Peak [RO]
Current Output Loudness
[RO]
Current Output Peak [RO]
Current Correction [RO]
Current Compression [RO]
Function
Enables the Loudness Control feature
Indicates the state of the AAP mode
Specifies the loudness level that will be targeted
Controls the amount of gain or attenuation that is
applied when loudness differences are measured
Specifies the highest measured loudness of the
input that will be permitted before attenuation is
applied
Specifies the lowest measured loudness of the input
that will be permitted before gain is applied
Specifies the size of a window in which small
loudness differences are allowed without the need
to change gain or attenuation
Controls the noise floor level
Controls how quickly the processing will respond to
sharp increases in loudness
Controls how quickly the processing will respond to
sharp decreases in loudness
Controls the amount of attenuation applied when
short-term peaks exceed the compressor threshold
Controls the amount of attenuation applied when
short-term peaks exceed the compressor threshold
Specifies the amount of loudness shaping desired
Specifies the threshold above which final limiting
will be applied
Activates the real-time meter.
Reports the smoothed input loudness measurement -60 dBEq to 20 dBEq
Reports the input peak measurement
Reports the smoothed output loudness
measurement
Reports the output peak measurement
Reports the amount of correction being applied
Reports the amount of compression being applied
Selenio X100
Installation and Operation Manual
Options
Enable
Disable
Uninitialized
Running
Not Running (bypassed)
Not Running
-40 dBEq to 0 dBEq
(-27 dBEq)
0% to 100% (90%)
0 dB to 20 dB
-20 dB to 0 dB
0.0 dB to 10.0 dB (1.0 dB)
-80 dBEq to -20 dBEq
(-50 dBEq)
5 ms to 150 ms (20 ms)
20 ms to 500 ms (120 ms)
0 dB to 16 dB (5 dB)
0% to 100% (40%)
0.0 to 1.0 (0.5)
-20 dBFS to 0 dBFS (0 dBFS)
Off
On
(0 dBEq)
-60 dBFS to 20 dBFS (0 dBFS)
-60 dBEq to 20 dBEq
(0 dBEq)
-60 dBFS to 20 dBFS (0 dBFS)
-60 dB to 60 dB (0 dB)
-60 dB to 60 dB (0 dB)