Sharp AR-BC260 Service Manual page 212

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

66
-43
Purpose
Setting
Function
PIC adjustment value writing (When the FAX is
(Purpose)
installed.)
Section
FAX
Item
Operation
Operation/
Before executing this simulation, the WRITE
Procedure
PROTECT jumper mounted on ICU PWB must be
changed.
1. Select a set item with the scroll key.
2. Enter a set value, and press [OK] button.
Item
A
CI_LEVEL_JUDGE
B
CI_CYCLE_MIN
C
CI_CYCLE_MAX
D
CI_RANGE
E
CI_COUNT
F
CI_DETECT
G
FNET_LEVEL_JUDGE
H
FNET_RANGE
I
FNET_TIME_OUT
J
FNET_COUNT
K
POFF_TIME
L
MSWON_LEVEL_JUDGE
PIC ADJUSTMENT VALUE WRITING.
A:
2
CI_LEVEL_JUDGE
2
B:
10
CI_CYCLE_MIN
C:
107
CI_CYCLE_MAX
[1~
15]
D:
5
CI_RANGE
66
-60
Purpose
Setting
Function
ACR data registration
(Purpose)
Section
FAX
Item
Operation
Operation/
1. Select a desired settimg item.
Procedure
2. Enter the number (0 - 9) with 10-key.
The entereed number is displayed on "NEW:"
column.
3. Press [SET] key.
The number entered in procedure 2 is saved in the memory
and displayed on "PRESENT" column.
Number
Item
Default
of digits
LocalCarrierNum
Null
Max. 6 Local Carrier Number
LongCarrierNum.
Null
Max. 6 Long-distance Carrier
OverCarrierNum.
Null
Max. 6 Overseas Carrier Number
Bypass Num.
9999
Max. 4 Bypass Number
User Area Code
Null
Max. 6 User Area Code
Machine Code
0601
Max. 4 Machine Code
Set range
Default
1 – 15
2
0 – 254
10
0 – 254
107
0 – 127
5
1 – 15
3
1 – 15
50
1 – 15
1
0 – 74
3
76 – 255
100
1 – 15
3
0 – 15
3
2 – 15
3
Display of the title line when
inputting a number
Number
AR-BC260 SIMULATION 9 - 74
Number
Item
Default
of digits
Version
0405
Max. 4 Version
Thru Num.1
0120
Max. 4 Through Number1
Thru Num.2
0140
Max. 4 Through Number2
Thru Num.3
0150
Max. 4 Through Number3
Thru Num.4
1060
Max. 4 Through Number4
Thru Num.5
1070
Max. 4 Through Number5
Thru Num.6
1080
Max. 4 Through Number6
Thru Num.7
0190
Max. 4 Through Number7
Thru Num.8
020
Max. 4 Through Number8
Thru Num.9
030
Max. 4 Through Number9
Thru Num.10
0330
Max. 4 Through Number10
Thru Num.11
0360
Max. 4 Through Number11
Thru Num.12
040
Max. 4 Through Number12
Thru Num.13
0450
Max. 4 Through Number13
Thru Num.14
050
Max. 4 Through Number14
Thru Num.15
0570
Max. 4 Through Number15
Thru Num.16
060
Max. 4 Through Number16
Thru Num.17
070
Max. 4 Through Number17
Thru Num.18
0750
Max. 4 Through Number18
Thru Num.19
080
Max. 4 Through Number19
Thru Num.20
0840
Max. 4 Through Number20
Thru Num.21
090
Max. 4 Through Number21
Thru Num.22
0990
Max. 4 Through Number22
Res. Thru Num.1
Null
Max. 4 Reserve Through Number1
Res. Thru Num.2
Null
Max. 4 Reserve Through Number2
Res. Thru Num.3
Null
Max. 4 Reserve Through Number3
Res. Thru Num.4
Null
Max. 4 Reserve Through Number4
Res. Thru Num.5
Null
Max. 4 Reserve Through Number5
Res. Thru Num.6
Null
Max. 4 Reserve Through Number6
Res. Thru Num.7
Null
Max. 4 Reserve Through Number7
Res. Thru Num.8
Null
Max. 4 Reserve Through Number8
67
67
-01
Purpose
Operation test/check
Function
Used to check the operations of printer DRAM read/
(Purpose)
write.
Section
Printer
Item
Operation
Operation/
When the machine enters the simulation mode, the
Procedure
printer DRAM read/write operation check is started.
After completion of check, "ERROR" or "MEMORY
SIZE" is displayed. If no memory is installed, "NA" is
displayed.