14
14
-0
Purpose
Clear/cancel (Trouble etc.)
Function
Used to cancel self diag troubles H3, H4, and H5.
(Purpose)
Inhibition of the color copy mode operation is
canceled.
Item
Trouble
Operation/
1. Press the [EXECUTE] key. (YES/NO key
Procedure
display)
2. When YES key is pressed, the following troubles
are cleared. (Cancel with NO key.)
(Trouble codes to be canceled)
Target trouble
codes
H3-00
Heat roller high temperature detection (HL1)
H3-01
Heat roller high temperature detection (HL2)
H4-00
Heat roller low temperature detection (HL1)
H4-01
Heat roller low temperature detection (HL2)
H5-01
Five continuous detections of POD1 not-
reached jam
15
15
-0
Purpose
Clear/cancel (Trouble etc.)
Function
Self diag U6-09 (large capacity paper feed tray)
(Purpose)
trouble cancel
Section
Paper feed
Item
Trouble
Operation/
Press the [EXECUTE] key to cancel the trouble.
Procedure
Press the [CLOSE] key to terminate the
simulation.
16
16
-0
Purpose
Clear/cancel (Trouble etc.)
Function
Used to cancel self diag trouble U2.
(Purpose)
Item
Trouble
Operation/
1. Press the [EXECUTE] key. (YES/NO key display)
Procedure
2. When YES key is pressed, the following troubles
are cleared. (Cancel with NO key.)
Error
Descriptions
Error
Error
AR-BC260 SIMULATION 9 - 21
(Trouble codes to be canceled)
Target trouble codes
U2-00
EEPROM read/write error (OPE)
U2-11
EEPROM check sum error (OPE)
U2-80
EEPROM read/write error (SCN)
U2-81
EEPROM check sum error (SCN)
U2-90
EEPROM read/write error (PCU)
U2-91
EEPROM check sum error (PCU)
17
17
-0
Purpose
Clear/cancel (Trouble etc.)
Function
Used to cancel self diag troubles PF (copy inhibition
(Purpose)
command from the host computer).
Section
Communication (RIC/MODEM)
Item
Trouble
Operation/
1. Press the [EXECUTE] key. (YES/NO key
Procedure
display)
2. When YES key is pressed, the following troubles
are cleared. (Cancel with NO key.)
(Trouble codes to be canceled)
Target trouble codes
PF-00
PC copy inhibition signal reception
21
21
-1
Purpose
Setting
Function
Used to set the maintenance cycle.
(Purpose)
Item
Specifications
Operation/
1. The current setup is displayed. (Highlighted)
Procedure
2. When the maintenance cycle is selected with the
key, the selected key is highlighted.
The maintenance message is displayed in every selected cycle.
When FREE is selected, the maintenance display is not shown.
(Cycle to be set)
Item
Set value
CYCLE
0
1
2
3
4
5
6
Descriptions
Error
Descriptions
Counter
Content
Default
5K
50K
10K
15K
40K
50K
100K
FREE

Advertisement