Display
TONER RANGE Y
Toner cartridge accumulated mileage time
(mm) (Y)
22
-19
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
Used to check the counters related to the network
(Purpose)
scanner.
Section
Network scanner
Item
Counter
Operation/
The counter values related to the network scanner
Procedure
are displayed.
(Counter values to be displayed)
Display
NETWORK
Network scanner document scan
SCANNER (BW)
number counter (B/W)
NETWORK
Network scanner document scan
SCANNER (COL)
number counter (Color)
SCANNER E-MAIL
Scanner e-mail transmit counter
SCANNER FTP
Scanner FTP transmit counter
TRIAL MODE
Trial mode counter
24
24
-1
Purpose
Data clear
Function
Used to clear the misfeed counter, the misfeed
(Purpose)
history, the trouble counter, and the trouble history.
(After completion of maintenance, the counters are
cleared.)
Section
Memory
Item
Counter
Operation/
1. Select the counter to be cleared.
Procedure
2. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
3. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
(Counter to be cleared)
Display
MACHINE JAM
Machine JAM counter
RSPF
Automatic document feeder JAM counter
TROUBLE
Trouble counter
Content
Content
Content
AR-BC260 SIMULATION 9 - 28
24
-2
Purpose
Data clear
Function
Used to clear the data of the number of uses (print
(Purpose)
quantity) of each paper feed section.
Section
Paper feed
Item
Counter
Operation/
1. Select the counter to be cleared. (The selected
Procedure
key highlighted.)
2. Press the [EXECUTE] key. The display for
reconfirmation to clear is shown.
3. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
After completion of maintenance, the following counters are
cleared.
(Counters to be cleared)
MFT TOTAL
Manual paper feed (total) counter
MFT HEAVY P1
Manual paper feed (heavy paper 1) counter
MFT HEAVY P2
Manual paper feed (heavy paper 2) counter
MFT OHP1
Manual paper feed (OHP1) counter
MFT OHP2
Manual paper feed (OHP2) counter
MFT ENV
Manual paper feed (Envelope) counter
TRAY1
Tray 1 counter
TRAY2
Tray 2 counter
TRAY3
Tray 3 counter
TRAY4
Tray 4 counter
ADU
Duplex unit counter
LCC
Large capacity tray counter
24
-3
Purpose
Data clear
Function
Used to clear the number of scan (read) of the
(Purpose)
staple and the document feed unit.
Section
Transport/Finisher
Item
Counter
Operation/
1. Select the counter to be cleared. (The selected
Procedure
key highlighted.)
2. Press the [EXECUTE] key. The display for
reconfirmation to clear is shown.
3. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
(Counters to be cleared)
Display
MIRROR SCAN
Scan counter
RSPF
Automatic document feeder counter
STAPLER
Staple counter
PUNCHER
Puncher counter
INVERTER
Inverter counter
Paper feed unit
Content