Sharp AR-BC260 Service Manual page 188

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

46
-16
Purpose
Adjustment
Function
Used to adjust the gamma and density.
(Purpose)
(Monochrome mode) (The adjustment check pattern
is printed.)
Section
Image process (ICU)
Item
Picture quality
Operation/
1. Select the adjustment point with the scroll key.
Procedure
2. Enter the adjustment value of the selected point
with the 10-key and press the [OK] key. (The
entered value is set.)
When the [EXECUTE] key is pressed, the color
balance adjustment check pattern corresponding to
the entered adjustment value is printed.
(Items to be set)
Display
A
POINT1
O
POINT15
46
-19
Purpose
Adjustment
Function
1. Used to set half tone (gamma) selection
(Purpose)
(destination setting) in the monochrome auto
copy mode.
2. Used to set the automatic exposure operation
mode (Monochrome copy mode, FAX mode,
monochrome scanner mode).
Section
Scanner (reading)
Item
Picture quality
Operation/
1. Select the adjustment mode with the scroll keys.
Procedure
2. Set the half tone density (gamma) with [MODE 1]
/ [MODE 2] keys.
3. Select the adjustment mode with the scroll keys.
4. Select the operation mode of the automatic
exposure mode with [ON]/[OFF] keys.
Display Set mode
Content
AE
MODE 1
The half-tone
MODE
(AUTO 1)
density is higher
than that of AUTO 2
mode.
MODE 2
The half-tone
(AUTO 2)
density is lower than
that of AUTO 1
mode.
Density
Min.
Max.
Default
Value
Value
373
627
500
373
627
500
Destination
Default
Japan
MODE 2
(AUTO 2)
Except
Japan
AR-BC260 SIMULATION 9 - 50
Setting
Display
Content
mode
AE
OFF
The automatic density (exposure)
STOP
control is performed on real time.
MODE
(The density level is changed
according to the document
pattern on real time.)
ON
The density at the lead edge of
the document is scanned, and the
overall density (exposure) level is
determined by the scanned
density level. (The overall density
level is fixed.)
46
-20
Purpose
Adjustment
Function
Used to adjust copy color balance (All color copy
(Purpose)
mode gamma/density adjustment) (All color copy
mode color balance/gamma/density are changed.)
Same as SIM 46-21, however, printing is not
performed.
Section
Image process (ICU)
Item
Picture quality
Operation/
1. Select the color to be adjusted with the color key
Procedure
(K/C/M/Y).
2. Select the adjustment point with the scroll key.
3. Enter the adjustment value of the selected point
with the 10-key and press the [OK] key. (The
entered value is set.)
(Items to be set)
Display
A
POINT1
O
POINT15
46
-21
Purpose
Adjustment
Function
Used to adjust copy color balance (All color copy
(Purpose)
mode gamma/density adjustment) (All color copy
mode color balance/gamma/density are changed.)
Section
Image process (ICU)
Item
Picture quality
Operation/
1. Select the color to be adjusted with the color key
Procedure
(K/C/M/Y).
2. Select the adjustment point with the scroll key.
3. Enter the adjustment value of the selected point with the 10-
key and press the [OK] key. (The entered value is set.)
When the [EXECUTE] key is pressed, the color balance
adjustment check pattern corresponding to the entered adjustment
value is printed.
Default
AE STOP
COPY: OFF
AE STOP
FAX: OFF
AE STOP
SCAN: ON
Color balance
Min.
Max.
Default
Value
Value
245
755
500
245
755
500
Color balance

Advertisement

Table of Contents
loading