Sharp AR-BC260 Service Manual page 143

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

Code
Function (Purpose)
Main
Sub
24
7
Used to clear the OPC drum
(membrane decrease) correction
counter. (This simulation is
performed with the OPC drum is
replaced.)
8
Used to clear the waste toner
counter in the transfer section.
9
Used to clear the printer mode
counter and the self-print mode print
counter. (After completion of
maintenance, the counters are
cleared.)
10
Used to clear the FAX counter.
(When the FAX is installed)
15
Used to clear the network scanner
counter.
25
1
Used to check the operation of the
process section (excluding the image
process section) and the toner
remaining quantity sensor. (The
toner remaining quantity sensor
output can be monitored.)
26
2
1. Used to set the paper size of the
large capacity tray. (When the
paper size is changed, the
software setup must be changed
accordingly with this simulation.)
2. Used to detect 8.5 " x 13" (INCH
Series) paper or documents and
to set the display mode. (All
paper feed modes)
3. Used to set the display form of
the paper kind in the manual
paper feed mode.
3
Used to set the auditor specification
mode. Setting must be made
according to the use conditions of the
auditor.
5
Used to set the count mode of the
total counter and the maintenance
counter.
6
Used to set the destination
specifications (paper, fixed copy
magnification ratios, image (process)
correction, machine operation in
case of an error, etc.).
10
Used to set the trial mode of the
network scanner.
18
Used to set YES/NO of toner save
operation. (This simulation is Enable
only for Japan and UK versions. It
depends on SIM 26-6 (Destination)
setting.
For the other destinations, the same
setting can be made by the user
program P22. (Effective only in the
monochrome copy mode)
35
Used to set whether the trouble
history display by SIM 22-4 is
displayed as one trouble or as the
accumulated number of continuous
troubles when two or more troubles
of same kind occur continuously.
38
Used to set "Continue/Stop" of
printing when the maintenance
timing (replacement timing of each
consumable part) is reached.
41
Used to set Enable/Disable of AMS
operation in the center-binding
mode.
49
Used to set the copy speed mode.
50
Used to set Black-White reverse,
group rounding, and scanner send
time display.
Purpose
Data clear
Process
(Photoconductor,
developing, transfer,
cleaning)
Data clear
Process
(Photoconductor,
developing, transfer,
cleaning)
Data clear
Printer
Data clear
FAX
Data clear
Scanner section
Operation test/check
Process
(Photoconductor,
developing, transfer,
cleaning)
Setting
Paper feed
Setting
Auditor
Setting
Setting
Setting
Scanner
Setting
Setting
Setting
Setting
Setting
Setting
AR-BC260 SIMULATION 9 - 5
Section
Photoconductor
Counter
Transfer
Counter
Counter
Counter
Counter
Operation
Specifications
Specifications
Specifications
Specifications
Specifications
Specifications
Specifications
Specifications
Specifications
Specifications
Specifications
Item
Photoconductor
Printer
Counter
Destination
Operation mode
(Common)
Operation mode
Operation mode