Compaq DESKPRO 2000 SERIES Maintenance & Service Manual page 48

Hide thumbs Also See for DESKPRO 2000 SERIES:
Table of Contents

Advertisement

Table 2-1
Continued
Message
1205-System Board I/O
Conflict Detected Device ID =
XXXYYYY
1720-IntelliSafe Hard Drive
detects imminent failure
1780-Disk 0 Failure
1781-Disk 1 Failure
1782-Disk Controller
1790-Disk 0 Failure
1791-Disk 1 Failure
1800-Temperature Alert
Hard Drive Parameter Table or
BIOS Error system Halted
IOCHECK Active Slot X
Bus Master Timeout Slot X
Invalid Electronic
Serial Number
Audible
(RESUME = F1 KEY)
* L = Long, S = Short
2-6
Troubleshooting
Beeps*
Probable Cause
2S
A system board device is conflicting
with an external add-in device.
None
Hard drive is about to fail.
None
Hard drive/format error.
None
Hard drive/format error.
None
Hard drive circuitry error.
None
Hard drive error or wrong
drive type.
None
Hard drive error or wrong
drive type.
None
Internal temperature exceeds
specification.
3L
Configuration or hardware failure.
None
Defective board in slot X.
None
Defective board in slot X.
None
Electronic serial number has
become corrupted.
2S
Power-on successful.
None
As indicated to continue.
Recommended Action
Run Computer Setup.
Back up contents and replace hard drive.
1. Run the Configuration
and Diagnostics utilities.
2. Replace hard drive.
1. Run the Configuration
and Diagnostics utilities.
2. Replace hard drive.
1. Run the Configuration
and Diagnostics utilities.
2. Replace hard drive.
1. Run the Configuration
and Diagnostics utilities.
2. Replace hard drive.
1. Run the Configuration
and Diagnostics utilities.
2. Replace hard drive.
Check that computer air vents are not blocked
and cooling fan is running.
Run the Configuration
and Diagnostics utilities.
Run the Configuration
and Diagnostics utilities.
Run the Configuration
and Diagnostics utilities.
Run Compaq Utilities.
None.
Press F1.

Hide quick links:

Advertisement

Table of Contents
loading