Starting System Inspection; Starter Motor Inspection (Te-Txc); Starter Motor; No-Load Test - Husqvarna 2013 TC 250R Workshop Manual

Husqvarna motorcycles 2013 te 250r; 2013 te 310r; 2013 te 310r usa; 2013 tc 250r; 2013 tc 250r usa; 2013 txc 250r usa; 2013 txc 310r usa
Table of Contents

Advertisement

TE 250R - 310R 2013 I.E. / TE 310R 2013 I.E. USA
Workshop Manual Ed. 07-2012
ELECTRICAL SYSTEM
TC 250R 2013 - TC 250R 2013 I.E. USA
TXC 250R - 310R 2013 I.E. USA

Starting system inspection

Starter motor inspection (TE-TXC)

Remove the starter motor (1) as described in the relevant paragraph.
Whenever a starter motor fault is detected, check the starter motor as follows:
- connect a meter across ground and starter motor contact.
- Check for continuity between the positive pole and motor ground. If no conti-
nuity is found, replace the starter motor. On assembly, apply a small amount of
LOCTITE 243 to the starter motor retaining screws.

Starter motor

Rated voltage: 12V
Current draw: 350 W

No-load test

Voltage: 11.2 V
Current: 30 A
Speed: 12,000 rpm

Cranking test

Voltage: 10 V
Current: 80 A
Torque: 3.5 Nm - 0.35 Kgm - 2.5 ft/lb

Starter motor test curves (TE-TXC)

1 - Output power (W)
2- Torque (TQ)
3- RPM (N: rpm. x 1000)
4 - Light voltage (V)
5 - Charging current (A)

Solenoid starter inspection (TE-TXC)

Disconnect the cables at the battery negative terminal to avoid possible short
circuits during disassembly. Disconnect the starter relay connector (A).
Disconnect the starter motor and battery positive cable wires at relay end. Apply
12 Volts to relay terminals (1) and (2) and check for continuity between terminals
B-M. Do not feed battery voltage to the relay longer than 5 seconds or the
relay might overheat, leading to winding damage. Use a multimeter to establish
whether the winding is open circuit or resistance exists. A winding in good condi-
tion will give the following resistance readings.
Meter scale setting: Ohm
Starter relay resistance. Standard: 3-6
H11129
M.26
.
Solenoid starter wiring
diagram
1= GROUND
2= + 12 V

Hide quick links: