Types Of Line Errors - HP ProCurve Secure 7000dl Series Basic Management And Configuration Manual

Secure router procurve 7000dl series
Hide thumbs Also See for ProCurve Secure 7000dl Series:
Table of Contents

Advertisement

Configuring E1 and T1 Interfaces
ProCurve Secure Router Modules
4-22
Table 4-4 lists the default settings for line error thresholds.
Table 4-4.
Threshold Commands
Setting
Description
BES
Bursty Errored Seconds
CSS
Controlled Slip Seconds
DM
Degraded Minutes
ES
Errored Seconds
LCV
Line Code Violations
LES
Line Errored Seconds
PCV
Path Coding Violations
SEFS
Severely Errored Framing Seconds
SES
Severely Errored Seconds
UAS
Unavailable Seconds
To set a line error threshold, enter the following command from the E1 or T1
interface configuration mode context:
Syntax: threshold [BES | CSS | DM | ES | LCV | LES | PCV | SEFS | SES | UAS] [15Min |
24Hr] <number of errors>
Use the 15Min option to set the thresholds for 15-minute intervals. Use the
24Hr option to set the threshold for 24-hour intervals. The time period for
these intervals is based on the past 15 minutes or 24 hours at any given
moment, not on set 15 minute or 24 hour blocks of time. By default, both 15
minute and 24 hour thresholds are set.

Types of Line Errors

The ProCurve Secure Router reports 10 types of line errors. Each line error
type has its own error triggers. Table 4-5 lists the line errors that the ProCurve
Secure Router reports and the triggers for each of these line errors.
15-Minute
24-Hour Default
Default
10
100
1
4
1
4
65
648
13340
133400
65
648
72
691
2
17
10
100
10
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 7102dl seriesProcurve 7103dl series

Table of Contents