CHECK POINTS FOR IMAGE PROBLEMS AT REGULAR INTERVALS
4.5 CHECK POINTS FOR IMAGE PROBLEMS AT
REGULAR INTERVALS
Image problems may appear at regular intervals that depend on the circumference
of certain components. The following diagram shows the possible symptoms (black
or white dots at regular intervals).
Colored spots at 54-mm intervals: Development roller
Abnormal image at 68-mm intervals: Transfer roller
Abnormal image at 188-mm intervals: Fusing belt
Abnormal image at 125-mm intervals: Pressure roller in the fusing unit
B051/B052
CÓPIA NÃO CONTROLADA
Paper feed
Problems at regular intervals
4-24
CÓPIA NÃO CONTROLADA
B051T801.WMF
SM