Field Service Ver. 1.0 Apr. 2005
6.2.3
CLEAR DATA
A. ADF BACKUP CLEAR (Di2011 Only)
Purpose/Use
To clear the values adjusted with ADF SENSOR ADJUST and the values adjusted with
Org. Width Detect.
✽
When PBA-CONT board has been replaced.
✽
When PBA-VR board has been replaced.
Setting/
1. Press the YES key to clear settings memorized in PBA-CONT.
Procedure
2. The operation stops automatically.
3. After clear the Backup data, adjust the ADF WIDTH ADJ. (MAX), ADF WIDTH ADJ.
(MIN) and ADF SENSOR ADJUST.
6. Service Mode
27