Field Service Ver. 1.0 Apr. 2005

11.6 Soft Switch List

Switch
Bit No.
No.
8
Detect CED or not after Dial
# 01
2/1
V.34 CI signal byte number reserved
8/7
Time between phase C to phase D signal in V.17
6
Header TX selection open to user
# 02
3/2
Transmit RTN signal level criteria
1
Sent N.G page
8
Send out NSF frame with station ID
7
Number of pause within phone number
# 03
6
Re-dial prohibit for NO ANSWER
4/3/2/1
RX level setting
4
Visible alarm for RTN signal
# 04
3
Audible alarm or RTN signal
1
Polarity change detection
8/7
Push Button on/off Timing (PB)
# 05
6/5
Relation between dialed No. and No. of dial pulse
4/3/2/1
Dial pulse make ratio select (MR)
8/7
Ring on time to ignore ring off time at 1st cycle
# 06
4/3
Ring off time at 1 st. cycle to approve incoming ring
8
Dial tone or busy tone detection
7
PSTN/ PBX setting
# 07
6
PBX dial tone detect
5
Dial mode select
4/3/2/1
Tx level select for PSK/ FSK
8
Sending RTN signal level
7
Detect busy tone after dialing
# 08
6
Sending CED signal after connection
4/3/2/1
Redial interval
8/7
Ringer frequency detection
# 09
5
TSI/ CSI Append "+"
2/1
Time from RX DIS signal to send DCS signal
8
Print out RTN page report
7
Confirmation report result field
6/5
Get gap time between digit for pulse dial
# 10
4
RX PIP T.30 command after send out MPS command
3
Received DIS signal within reception
2
Transmission time limitation
1
Audio alarm after communication fail
Designation
11. Soft Switch Set
Page No.
114
114
115
116
117
118
118
119
120
121
109