Field Service Ver. 1.0 Apr. 2005
11.7.38

SOFT SWITCH: #38

Bit
Designation
No.
Fine tune of 33.6 kbps/
8
31.2 kbps receiving
speed for V.34 modem
Set/Reset V.34 transmit
7
level deviation
6
V.34 flag number
between ECM frame
5
Phase 2 guard tone
4
power level (V.34)
3
Reserved
2
Polling RX start speed
1
V.8 /V.34 capability
• Bit 8
: This bit when set to 1 can get higher speed communication for V.34 under the
same line condition.
11.7.39

SOFT SWITCH: #39

Bit
Designation
No.
Disable V.34 TX for V.34
8
modem
Disable V.34 RX for V.34
7
modem
6
Flags number in FSK for
V.34 modem
5
Manual TX mode for
4
V.34 modem
Switch from V.17 to V.34
3
if DIS bit 6 set after
received DIS
2
Delay time in primary
channel for V.34 transmit
1
after CFR or MCF signal
Function
0 : No - modem default setting
1 : Yes
0 : Reset
1 : Set
Flags number
2
Bit 6
0
Bit 5
0
0 : normal power level
1 : -7 db of normal power level
Reserved
0 : start from V.34
1 : start from V.17
0 : No
1 : Yes
Function
0 : No
1 : Yes
0 : No
1 : Yes
Flags number
1
Bit 6
0
Bit 5
0
0 : V.8 - start handshake from V.8
1 : V.17
0 : Yes - start V.8 handshaking.but only first time
1 : No - Continue start with V.17
Delay time
100 ms 200 ms 300 ms 500 ms
Bit 2
0
Bit 1
0
11. Soft Switch Set
4
8
16
0
1
1
1
0
1
2
3
4
0
1
1
1
0
1
0
1
1
1
0
1
Initial
Setting
Bit
HEX
1
1
E
1
0
0
0
1
0
1
Initial
Setting
Bit
HEX
0
0
0
0
0
0
0
1
0
1