Field Service Ver. 1.0 Apr. 2005
B. PRN MAIN REGIST
Functions
• To adjust by varying the starting position of image writing in the main scanning direc-
tion.
Use
• If the image on the copy deviates in the main scan direction
• When the PH unit has been replaced
Adjustment
Specification
Adjustment
If width A on the test pattern is longer than the specifications, decrease the setting value.
Instruction
If width A on the test pattern is shorter than the specifications, increase the setting
value.
Adjustment
1. Load the Paper Feed Tray/1 with A4 crosswise paper.
Procedure
2. Enter Function of the Service mode.
3. Select "Print Test Pattern" and then "Test Pattern1." Then, press the Start key.
4. This will produce a test pattern.
5. Check to see if width A on the test pattern falls within the specified range.
6. If width A falls outside the specified range, perform the following steps to make an
adjustment.
7. Select "Adjust" of "PRN Main Regist."
8. Using [
9. Press the [Yes] key to validate the setting value selected in step 6.
NOTE
• If a single adjustment procedure does not successfully bring width A into the
specified range, repeat steps 5 through 7.
A
4035D519AA
/
] key, select the appropriate setting value.
• Adjust so that width A on the test pattern pro-
duced falls within the specified range.
Specifications
20 ± 2.0 mm
Setting Range
60 to 140 (1 step = 0.1 mm)
The default setting is "100"
8. Service Mode