6. Service Mode
C. ADF WIDTH ADJ. (MAX)
Purpose/Use
To adjust the original size detection VR.
✽
When PBA-VR board is replaced
Adjustment
1. Display the Tech. Rep. mode.
Procedure
2. Choose "ADF WIDTH ADJ. (MAX)" from "Functions".
D. ADF WIDTH ADJ. (MIN)
Purpose/Use
To adjust the original size detection VR.
✽
When PBA-VR board is replaced
Adjustment
1. Display the Tech. Rep. mode.
Procedure
2. Choose "ADF WIDTH ADJ. (MIN)" from "Functions".
E. ADF SENSOR ADJUST
Purpose/Use
To automatically adjust the detection level of original path sensor.
✽
When each sensor is replaced
✽
When original size detection error occurs
Setting/
1. Display the Tech. Rep. mode.
Procedure
2. Choose "ADF WIDTH ADJUST" from "Functions".
3. Press the YES key.
26
Field Service Ver. 1.0 Apr. 2005
3. Align the original edge plane of the Side
Edge Stop of the Original Feed Tray to the
outside ▼ mark.
4. Press the YES key to determine the maxi-
mum value.
5. Power cycle and check whether size
detection operates normally.
4344D540AA
3. Align the original edge plane of the Side
Edge Stop of the Original Feed Tray to the
inside ▼ mark.
4. Press the YES key to determine the mini-
mum value.
5. Power cycle and check whether size
detection operates normally.
4344D541AA