Field Service Ver. 1.0 Apr. 2005
8.3.2
Misfeed at the Multiple Bypass Paper Take-up Section
A. Detection Timing
Type
Paper take-up
• The leading edge of the paper does not unblock the Synchronizing Roller Sen-
section misfeed
detection
• The Synchronizing Roller Sensor (PC1) is not blocked even after the lapse of a
Size error detection
• The Synchronizing Roller Sensor (PC1) is blocked before the lapse of a given
B. Action
Synchronizing Roller Sensor (PC1)
Paper Take-up Solenoid (SL21/MB)
Step
Operations
1
Initial checks
2
PC1 sensor check
3
SL21/MB operation check
4
Replace PWB-A
sor (PC1) even after the lapse of a given period of time after the Paper Take-up
Solenoid (SL21/MB) has been energized.
given period of time after the paper has unblocked the Synchronizing Roller
Sensor (PC1).
period of time.
Relevant Electrical Components
Ref.
Page
☞
☞
Description
Master Board (PWB-A)
WIRING DIAGRAM
Control signal
–
–
21
PWB-A PJ17A-3 (ON)
22
PWB-A PJ12A-2 (REM)
–
–
8. Jam Display
Location
(Electrical
Components)
–
F-8
D-16
–
27