UP Mode Settings for IEEE 1394

Enter the UP mode. Then do the procedure below to perform the initial interface
settings for IEEE 1394. These settings take effect every time the machine is
powered on.
1. Press the "User Tools/Counter"key.
2. On the touch panel, press "System Settings".
3. Press "Interface Settings".
4. Press "IEEE1394".
5. Press the following soft keys on the touch panel. Then select the following
settings:
• "IP Address"
Select the "AUTO-Obtain (DHCP) " or "Specify". When you select "Specify",
you can set the IP Address and Subnet Mask manually.
• "IP over 1394"
Enable or disable this setting as required. This setting enables IP over 1394
as the default setting for the printing method.
• "SCSI Print"
Enable or disable this setting as required. This setting enables SCSI Print as
the default setting for the printing method.
• "Bi-directional SCSI Print"
Switch bi-directional printing on or off for SCSI print.

SP Mode Settings for IEEE 1394

The following SP commands can be set for IEEE 1394.
SP No.
Name
5839 004
Host Name
5839 007
Cycle Master
5839 008
BCR Mode
5839 009
IRM 1394a
Check
5839 010
Unique ID
5839 011
Logout
5839 012
Login
5839 013
Login MAX
SM
CÓPIA NÃO CONTROLADA
Sets the name of the device used on the network.
Example: RNPXXXXXXXXXX
Enables or disables cycle master function of the IEEE
1394 standard bus.
Sets the BCR (Broadcast Channel Register) setting for
the Auto Node operation for the standard IEEE1394 bus
for when IRM is not in use. The following three settings
are available: "Standard," "IRM Color Copy," and
"Always Effective."
Determines whether an IRM check for IEEE 1394a is
conducted for the Auto Node when IRM is not used.
Enables the "Node_Unique_Id" setting for enumeration
on the standard IEEE 1394 bus.
Determines how successive initiator login requests are
handled during login in for SBP-2.
Enables or disables exclusive login for SBP-2.
Sets the limit for the number of logins for SBP-2. Range:
1 ~ 62.
1-53