SERVICE PROGRAM MODE
Mode No.
5
(Class 1, 2, and 3)
816
Remote Service
1
I/F Setting
2
CE Call
3
Function Flag
4
Communicate Test
Call
5
Device Information
Call
6
Device Information
Call Display Setting
7
SSL Disable
8
RCG Connect Timeout
9
RCG Write Timeout
10
RCG Read Timeout
11
Port 80 Enable
821
Remote Service Address
1
CSS-PI device code
2
RCG IP Address
B156/B220
CÓPIA NÃO CONTROLADA
Selects the remote service setting.
[0 ~ 2 / 2 / 1 /step]
• 0: Remote service off
• 1: CSS remote service on
• 2: NRS remote service on
Performs the CE Call at the start or end of the service.
[0 ~ 1 / 0 / 1 /step]
• 0: Start of the service
• 1: End of the service
This SP is activated only when SP 5816-001 is set to
"2".
Enables/disables the remote service function.
[0 ~ 1 / 0 / 1 /step]
• 0: Disabled
• 1: Enabled
Communication Test Call
Device Information Call
Displays/does not display the device information call
content.
[0 ~ 1 / 0 / 1 /step]
• 0: Not displayed
• 1: Displayed
Uses/does not use the RCG certification by SSL when
calling the RCG.
[0 ~ 1 / 0 / 1 /step]
• 0: Uses the RCG certification
• 1: Does no use the RCG certification
Specifies the connect timeout interval when calling the
RCG.
[1 ~ 90 / 10 / 1 second/step]
Specifies the write timeout interval when calling the
RCG.
[0 ~ 100 / 60 / 1 second/step]
Specifies the read timeout interval when calling the
RCG.
[0 ~ 100 / 60 / 1 second/step]
Enables/disables the access via port 80 to the SOAP
(Simple Object Access Protocol) method.
[0 ~ 1 / 0 / 1 /step]
• 0: Disabled
• 1: Enabled
Selects the PI device code.
[0 ∼ 4 / 0 / 1 /step]
To validate the setting, turn off and on the main power
switch.
Sets the RCG IP address for calling the center.
5-36