[C]
7. Remove the rear scale [A] ( x 3), left scale [B] ( x 2), and exposure glass
[C].
NOTE: When installing the exposure glass, make sure that the mark [D] is
positioned at the rear left corner, as shown.
8. Install the anti-condensation heater [E] ( x 2,  x 1).
9. Reinstall the exposure glass and the scales.
SM
CÓPIA NÃO CONTROLADA
[A]
B156I528.WMF
1-67
CÓPIA NÃO CONTROLADA
ANTI-CONDENSATION HEATER
[E]
B156I529.WMF