Ricoh B156 Service Manual page 703

Gestetner, lanier, savin
Table of Contents

Advertisement

IP Fax Switch 03
No.
FUNCTION
0
Effective field limitation for G3
standard function information
0: OFF, 1: 4byte (DIS)
1
Switching between G3 standard
and G3 non standard
0: Enable switching
1: G3 standard only
2
AI modem rate function
0: OFF, 1: ON (enable)
3
ECM frame size selection at
transmitting
0: 256byte, 1: 64byte
4
DIS detection times for echo
prevention
0: 1 time, 1: 2 times
5
CTC transmission selection
0: PPRx1
1: PPRx4
6
Shift down setting at receiving
negative code
0: OFF, 1: ON
7
Not used
IP Fax Switch 04
No.
FUNCTION
0
TCF error threshold
1
2
3
4-7
Not used
SM
CÓPIA NÃO CONTROLADA
When "0" is selected, the transmission
condition is decided by error frame numbers.
When "1" is selected, the transmission
condition is based on the ITU-T method.
Do not change this setting.
Sets the TCF error threshold level.
[00 to 0f]
The default is "1111" (0fH).
Do not change these settings.
89
CÓPIA NÃO CONTROLADA
BIT SWITCHES
SP No. 1-111-004
COMMENTS
SP No. 1-111-005
COMMENTS