Ricoh B156 Service Manual page 714

Gestetner, lanier, savin
Table of Contents

Advertisement

NCU PARAMETERS
Address
6805AF
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (high byte)
6805B0
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (low byte)
6805B1
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (high byte)
6805B2
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (low byte)
6805B3
Detection time for 800 Hz AI short
protocol tone
6805B4
PSTN: Tx level from the modem
6805B5
PSTN: 1100 Hz tone transmission
level
6805B6
PSTN: 2100 Hz tone transmission
level
6805B7
PABX: Tx level from the modem
6805B8
PABX: 1100 Hz tone transmission
level
6805B9
PABX: 2100 Hz tone transmission
level
6805BD
Modem turn-on level (incoming
signal detection level)
6805BE
Not used
to
6805C6
6805C7
Bits 0 to 3 – Not used.
Bit 4 – V.34 protocol dump 0: Simple, 1: Detailed (default)
Bits 5 to 7 – Not used.
6805C8
Not used
to
6805D9
6805DA
T.30 T1 timer
6805E0
Maximum wait time for post
bit 3
message
6805E5
Signal Detection Method
B750
CÓPIA NÃO CONTROLADA
Function
100
CÓPIA NÃO CONTROLADA
Unit
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
Hz(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
20 ms
Factory setting: 360 ms
-N – 3 dBm
SP2-103-002 (parameter
01).
- N 6805B4 - 0.5N 6805B5 –3.5 (dB)
See Note 7.
- N6805B4 - 0.5N 6805B6 –3 (dB)
See Note 7.
- dBm
- N 6805B7 - 0.5N 6805B8 (dB)
- N 6805B7 - 0.5N 6805B9 (dB)
-37-0.5N
(dBm)
Do not change the
settings.
Do not change the
settings.
1 s
0: 12 s
1: Maximum wait time for
post message
1: 30 s
(EOP/EOM/MPS) can be
changed to 30 s.
Change this bit to "1" if
communication errors
occur frequently during
V.17 reception.
80h: Auto
Signal detection method,
Edge
Auto Edge (80h) or Fixed
81h or 83h:
Edge (81h or 83h).
Fixed Edge
Rev. 03/2006
Remarks
SM

Hide quick links:

Advertisement

Table of Contents