Ricoh B156 Service Manual page 706

Gestetner, lanier, savin
Table of Contents

Advertisement

BIT SWITCHES
IP Fax Switch 03
No.
0-1
T1 timer adjustment
Adjusts the T1 timer.
The default is "00" (35 seconds).
2-3
T4 timer adjustment
Adjust the T4 timer.
The default is "00" (3 seconds).
4-5
T0 timer adjustment
Bit 5
Bit 4
0
0
0
1
1
0
1
1
Adjusts the fail safe timer. This timer sets the interval between "setup" data
transmission and T.38 phase decision.
If your destination return is late on the network or G3 fax return is late, adjust the
longer interval timer.
The default is "00" (75 seconds).
6-7
Not used
B750
CÓPIA NÃO CONTROLADA
FUNCTION
75 sec
120 sec
180 sec
240 sec
CÓPIA NÃO CONTROLADA
COMMENTS
Bit 1
Bit 0
0
0
35 sec
0
1
40 sec
1
0
50 sec
1
1
60 sec
Bit 3
Bit 2
0
0
3 sec
0
1
3.5 sec
1
0
4 sec
1
1
5 sec
Do not change these settings.
92
SP No. 1-111-004
SM

Hide quick links: