7. Pass the connector [A] through the opening [B].
8. Install the tray heater [C] ( x 1).
9. Connect the heater connector [D] to the cable [E].
10. Remove the oil tank [F].
NOTE: Hang the left oil pipe [G] in the notch [H] in the controller box. Then, oil
does not fall from the pipe to the floor.
11. Install the clamp [I].
NOTE: Make sure that the ac cable [J] from the main machine goes behind the
bracket [K].
12. Connect the cable to the ac cable [J]. Then attach the cable with the clamp.
13. Install the oil tank and the rear covers.
NOTE: When you install the oil tank, make sure that the position of the mark
[L] on the oil pipe is as shown in the diagram above. If you do not do
this, the oil is not correctly supplied to the fusing unit.