Field Service Ver. 1.1 Jun. 2010
14.4 Solution
14.4.1
0010: Color PC drum motor malfunction
Color PC drum motor (M4)
Step
1
Check the connector between M4-PRCB
PJ5 for proper connection and correct as
necessary.
2
Check the M4 connector for proper drive
coupling and correct as necessary.
3
M4 operation check
4
Change M4.
5
Change PRCB.
14.4.2
0017: Main motor malfunction
Main motor (M2)
Step
1
Check the connector between M2-PRCB
PJ6 for proper connection and correct as
necessary.
2
Check the M2 connector for proper drive
coupling and correct as necessary.
3
M2 operation check
4
Change M2.
5
Change PRCB.
Relevant electrical parts
Action
Relevant electrical parts
Action
14. MALFUNCTION CODE
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ5-3 to 6
-
-
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ6-3 to 6
-
-
Location (electri-
cal component)
-
-
B-15
-
-
Location (electri-
cal component)
-
-
C-15
-
-
207