Cooling System - Chery automobile Service Manual

Chery
Hide thumbs Also See for automobile:
Table of Contents

Advertisement

COOLING SYSTEM

Cooling System
Capacity of Coolant
Fan
Water pump
Radiator
Thermostat
Thermal switch
CTS
Parameters
Overall system capacity L
Engine capacity L
Radiator capacity L
Capacity of expansion tank L
Diameter: 280mm
Number of blades: 6
Working voltage: 9-15V
Rotating speed: Gear I: High-speed motor 2000
Low-speed motor 1800 200
Rotating speed: Gear II: High-speed motor 2800 200
Low-speed motor 2600 200
Diameter of impeller:
Gear ratio: 1.053: 1
Opening force of pressure cap: 160kPa
Front face area 0.202m²
Radiation area 8.93m²
Opening temperature 85º-89º
Full open temperature 99º-102º
Switch-on temperature Gear I 95 Cº
Switch-off temperature Gear I 84 Cº Gear II 91 Cº
Working voltage: 12V
Resistance : 70
90
110
124
TD-11
8
3.3
2.1
0.4
72mm
Temperature Cº: 159 21.3
86.7 11
52.3 6.3
28.2 2.8
200
Gear II 102 Cº

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A series