4602
Scanner Memory Access
001 Scanner Memory Access
002 Address Setting
003 Data Setting
4603
AGC Execution
002 HP Detection Enable
003 HP Detection Disable
FGATE Open/Close
Opens or closes the FGATE signal. This SP automatically returns to the
4604
default status (close) after exiting this SP.
[0 to 1 / 0 / 1]
0: OFF, 1: ON
White Balance Target: R
This value is the target value of red for the white level adjustment (CS model
4606
only).
[0 to 1023 / 784 / 1 digit]
4607
White Balance Target: G
This value is the target value of green for the white level adjustment.
001
CS: [1023 to 0 / 784 / 1 digit]
MS: [1023 to 1 / 876 / 1 digit]
SM Appendix
Enables the read and write check for the
SBU registers.
Not used
Executes the AGC with the scanner detection.
Executes the AGC with the scanner detection.
4-49
D009/D011/D012/D013/D091/D092
System SP Table-4