Detailed Self-Diagnostic Mode; Executing Detailed Self-Diagnosis - Ricoh D009 Service Manual

Hide thumbs Also See for D009:
Table of Contents

Advertisement

5.7.3 DETAILED SELF-DIAGNOSTIC MODE

In addition to the self-diagnostic test initiated every time the main machine is powered on,
you can set the machine in a more detailed diagnostic mode manually in order to test other
components or conditions that are not tested during self-diagnosis after power on. The
following device is required in order to put the machine in the detailed self-diagnosis mode.
No.
Name
G02119350
Parallel Loopback Connector

5.7.4 EXECUTING DETAILED SELF-DIAGNOSIS

Follow this procedure to execute detailed self-diagnosis.
1.
Switch off the machine, and connect the parallel loopback device to the Centronics I/F
port.
2.
Hold down
, press and hold down
same time, switch on the machine.
You will see "Now Loading" on the touch-panel, and then you will see the results of the
test.
A report is printed every time a detailed self-diagnostic test is executed, whether errors
were detected or not.
SM
, and then while pressing both keys at the
5-25
D009/D011/D012/D013/D091/D092
Self-Diagnostic Mode

Hide quick links:

Advertisement

Table of Contents
loading